Vega VEGABAR 40 4 … 20 mA Manuale Utente

Navigare online o scaricare Manuale Utente per Apparecchiature Vega VEGABAR 40 4 … 20 mA. VEGA VEGABAR 40 4 … 20 mA User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Operating Instructions

pLevel and PressureOperating InstructionsVEGABAR 40 (4 … 20 mA)iZEROSPANtOPERATE VEGADIS 10E12AM10+4...20mA+--123 5678 VEGADIS 10E12AM10+4...20mA+

Pagina 2 - Note Ex area

10 VEGABAR 40 (4 … 20 mA)Product description7285~7682Pg 13,5~76M20x1,59082~768290½" NPT156781.5 DimensionsHousing without indicating module with

Pagina 3 - Contents

VEGABAR 40 (4 … 20 mA) 11GP20G ¼G ½ A87ø17,53SW 27GR20ø11,4G ½ A87ø17,53SW 27GN251520SW 27¼" NPT½" NPT92GA2520ø11,4½" NPT92SW 27GB25ø3M

Pagina 4 - 1 Product description

12 VEGABAR 40 (4 … 20 mA)Mounting, electrical connection2 Mounting2.1 Mounting instructionsVEGABAR can be mounted in any position.Cable entries must p

Pagina 5 - 1.3 Technical data

VEGABAR 40 (4 … 20 mA) 130 - 20 bar8765321–+0 - 20 barVEGABAR with indicating moduleFunctionground 1)Ammeter for local controlSupply voltage12 … 36 V

Pagina 6

14 VEGABAR 40 (4 … 20 mA)Supply via a PLC with active input circuitProcessing is carried out via a PLC with active input circuit.+ – –1 2

Pagina 7 - Electrical data

VEGABAR 40 (4 … 20 mA) 154 SetupElectrical connection and setup can be sim-plified by temporarily mounting the cover orthe indicating module on VEGABA

Pagina 8 - 8 VEGABAR 40 (4 … 20 mA)

16 VEGABAR 40 (4 … 20 mA)Setup2 Adjustment of span(e.g. process pressure or level at maximum)• Set rotary switch to span.• By pushing the "+“ and

Pagina 9 - Operating conditions

VEGABAR 40 (4 … 20 mA) 17Depending on parameter:change value (increase) orchoose from listChoose menu item or interruptinputAcc. to the menu item, sav

Pagina 10 - 10 VEGABAR 40 (4 … 20 mA)

18 VEGABAR 40 (4 … 20 mA)SetupMenu schematicAd-just-mentCalcu-lationOutput Simula-tionOperate0.2mbarEscapeAdjustwithpress.Adjustwithoutpress.EscapeZer

Pagina 11 - Product description

VEGABAR 40 (4 … 20 mA) 19SetupAddi-tionalfunct.EscapeSensordataLan-guageLan-guageEnglishResetP max150mbarTemp.30.7°CFabr.-Date49.98P min-0.3mbarReset

Pagina 12 - 3 Electrical connection

2 VEGABAR 40 (4 … 20 mA)Safety information, Note Ex areaSafety informationPlease read this manual carefully, and also takenote of country-specific ins

Pagina 13 - 0 - 20 bar

20 VEGABAR 40 (4 … 20 mA)SetupAdjustment taking the current pres-sure into account (live adjustment)The live adjustment comprises two steps:1 Adjustme

Pagina 14 - Supply via power supply unit

VEGABAR 40 (4 … 20 mA) 21Setup3 Adjustment of zeroAdjust zero with the "+“ or "–“ keyand save with the "OK“ key.4 Adjustment of spanAdj

Pagina 15 - Adjustment

22 VEGABAR 40 (4 … 20 mA)SetupSimulationYou can adjust with the "+“ and "-“key an individual pressure or %value to check the outputs of VE-

Pagina 16 - Integration time

VEGABAR 40 (4 … 20 mA) 23Diagnostics5 Diagnostics5.1 MaintenanceVEGABAR process pressure transmitters aremaintenance-free.5.2 Failure rectificationFau

Pagina 17 - Adjustment elements

24 VEGABAR 40 (4 … 20 mA)Diagnostics~1 2 3+–––+mAVoltage CurrentVExternalenergy sourceAmmeter for localcontrolmAChecking pressure compensationOp

Pagina 18 - Menu schematic

VEGABAR 40 (4 … 20 mA) 25Instrument modification6 Instrument modification6.1 Exchange of adjustmentmodulesThe modular construction of VEGABAR allowsre

Pagina 19 - 1) 1) 1)

26 VEGABAR 40 (4 … 20 mA)Instrument modification6.2 Exchange of electronicsYou first have to remove the adjustment mod-ule as described in chapter &qu

Pagina 20 - 3 Adjustment of zero

VEGABAR 40 (4 … 20 mA) 276.3 Exchange of the process fittingThe process fitting on VEGABAR 40 can beeasily exchanged.• First loosen the three screws o

Pagina 21 - Evaluation

ISO 9001The statements on types, application, use and operating conditions ofthe sensors and processing systems correspond to the latest infor-mation

Pagina 22 - Additional functions

VEGABAR 40 (4 … 20 mA) 3ContentsContentsSafety information ... 2Note Ex area ...

Pagina 23 - 5 Diagnostics

4 VEGABAR 40 (4 … 20 mA)Product description1 Product description1.1 Function and configurationVEGABAR 40 process pressure transmittersare efficient in

Pagina 24 - 1 2 3

VEGABAR 40 (4 … 20 mA) 5Product description1.3 Technical dataMechanical dataMaterials, wetted partsProcess connection brass 2.041, stainless steel 1.4

Pagina 25 - 6 Instrument modification

6 VEGABAR 40 (4 … 20 mA)Product descriptionNominal measuring rangeGauge pressure resistanceLow pressure resistanceGauge pressure0…0,1 bar / 0…10 kPa 1

Pagina 26 - 26 VEGABAR 40 (4 … 20 mA)

VEGABAR 40 (4 … 20 mA) 7Product descriptionElectrical dataAdjustment rangesZero adjustable from -20 … +95 % of nominal rangeSpan adjustable from 3,3 …

Pagina 27 - Hexagon head

8 VEGABAR 40 (4 … 20 mA)1)Relating to the nominal measuring range.2)In the compensated temperature range of 0°C … +80°C, reference temperature 20°C.3)

Pagina 28 - ISO 9001

VEGABAR 40 (4 … 20 mA) 9Product descriptionOperating conditionsAmbient conditionsAmbient temperature -40°C … +85°C- with indicating module -20°C … +70

Commenti su questo manuale